Komersial Inverter Air ka Kolam Renang Cai Pompa Panas
Video
Kontrol sentral
HEEALARX komérsial inverter kolam renang pompa panas datang equipping kalawan kontrol terpusat, sahingga adjustment hawa sarta gagalna ngarévisi loba gampang. Kalayan integrasi kontrol master-budak kana desain sistem, unit master tiasa damel sareng efisiensi anu langkung luhur tanpa diganggu ku kagagalan unit simpen nalika operasi.
R32 Refrigerant Sadia
rentang pinuh HEEALARX inverter komérsial pompa panas kolam renang lumaku refrigerant R32 kalawan GWP lemah sareng efisiensi cooling pemanasan luhur. HEEALARX INDUSTRY LIMITED ogé mangrupikeun sababaraha produsén pompa panas kolam renang komérsial anu ngadopsi refrigerant R32 pikeun pompa panas kolam renang inverter komérsial. Biasana pikeun pompa panas kolam renang inverter komérsial ngagunakeun refrigerant R410A.
Téhnologi Defrosting otomatis
HEEALARX komérsial inverter kolam renang pompa panas adopts téhnologi defrosting otomatis, nu bisa nangtukeun waktu defrosting nurutkeun kaayaan operasi unit, hawa ambient sarta ketebalan ibun, ku kituna pikeun ngahontal defrosting otomatis lamun diperlukeun. Ukuran ieu tiasa ngirangan waktos defrosting ku 20% sareng ogé tiasa mastikeun kapasitas pemanasan anu luhur.
Digital Toel WIFI Control
Kalayan kontrol wifi / aplikasi, palanggan tiasa ngontrol pompa panas kolam renang inverter komérsial dimana waé kalayan aplikasi dina smartphone anjeun, gampang pikeun pangropéa.
Parameter produk
Spésifikasi Pompa Panas Kolam renang Inverter DC | |||||||||
Modél | MX400IN | MX500IN | MX600IN | MX800IN | MX1000IN | MX1300IN | MX2400IN | MX3000IN | |
Sasayogian tanaga | 3 / 380-415V / 50HZ | ||||||||
Pemanasan: (Air26℃,Cai26℃,Kalembaban 80%) | Kapasitas (KW) | 44 | 55 | 66 | 83 | 110 | 140 | 240 | 330 |
COP | 14.18-5.88 | 14.28-5.92 | 14.21-5.74 | 14.30-5.78 | 14.44-5.74 | 14.52-5.69 | 14.38-5.59 | 14.25-5.64 | |
COP dina kapasitas 50%. | 10.09 | 10.16 | 10.45 | 10.52 | 10.83 | 10.57 | 10.06 | 10.68 | |
Pemanasan: (Air20℃, Cai26℃Kalembaban 80%) | kapasitas (KW) | 40 | 50 | 60 | 75 | 100 | 125 | 200 | 300 |
COP | 8.30-5.05 | 8.33-5.08 | 8.35-5.08 | 8.24-5.02 | 8.34-5.10 | 8.29-5.12 | 8.25-5.08 | 8.24-5.03 | |
COP dina kapasitas 50%. | 8.05 | 8.12 | 8.12 | 8.15 | 8.23 | 8.21 | 8.21 | 8.15 | |
Pemanasan;(Air15℃, Cai26℃,Kalembaban70%) | kapasitas (KW) | 34 | 42 | 50 | 65 | 85 | 105 | 175 | 250 |
COP | 6.02-4.01 | 6.05-4.05 | 6.04-4.02 | 6.09-4.06 | 6.05-4.08 | 6.07-4.11 | 6.09-4.08 | 6.08-4.10 | |
COP dina kapasitas 50%. | 6.18 | 6.25 | 6.22 | 6.28 | 6.24 | 6.22 | 6.28 | 6.19 | |
Tiis;(Air35℃, Cai28℃,Kalembaban70%) | kapasitas (KW) | 32 | 40 | 48 | 60 | 80 | 102 | 165 | 240 |
HONOR | 5.62-3.50 | 5.68-3.54 | 5.67-3.54 | 5.70-3.51 | 5.66-3.49 | 5.67-3.51 | 5.69-3.48 | 5.68-3.48 | |
EER dina kapasitas 50%. | 3.43 | 3.45 | 3.42 | 3.47 | 3.43 | 3.44 | 3.45 | 3.47 | |
Kakuatan asupan deui dina hawa 20℃(KW) | 4.81-7.92 | 6.00-9.84 | 7.18-11.81 | 9.10-14.94 | 11.99-19.60 | 15.07-24.41 | 24.24-39.37 | 36.40-59.64 | |
Reted arus input dina hawa 20℃(A) | 7.69-12.68 | 9.54-15.74 | 11.13-18.88 | 14.55-23.94 | 19.17-31.34 | 24.10-39.04 | 38.59-62.96 | 58.21-95.35 | |
aliran cai | m3/jam | 18-20 | 20-25 | 25-30 | 30-35 | 40-45 | 60-65 | 80-85 | 120-125 |
Kompresor | HITACHI | ||||||||
Panukeur panas | Pipa titanium spiral dina PVC | ||||||||
Tekanan min/tekanan max | Mpa | 1,5 / 4,20 | |||||||
ukuran net unit | mm | 1420x730x1050mm | 1480x850x1550mm | 1480x850x1550mm | 1480x850x1550mm | 1850 x 1000 x 1940 mm | 2000 x 1100 x 1920 mm | 2020 x 1055 x 1900 mm | 2239 x 1185 x 2060 mm |
beurat bersih | kg | 450 | 450 | 650 | 650 | 870 | 1250 | 1520 | 1987 |
noise dina 1 m | dB(A) | 60-65 | 60-65 | 62-68 | 62-68 | 65-70 | 65-70 | 65-72 | 65-72 |